nomadix wireless receiver with ecg amplifier (BIOPAC)
Structured Review

Nomadix Wireless Receiver With Ecg Amplifier, supplied by BIOPAC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/nomadix+wireless+receiver+with+ecg+amplifier/nomadix+wireless+receiver+with+ecg+amplifier/pmc06773734-110-14-16
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "Speckleplethysmographic (SPG) Estimation of Heart Rate Variability During an Orthostatic Challenge"
Article Title: Speckleplethysmographic (SPG) Estimation of Heart Rate Variability During an Orthostatic Challenge
Journal: Scientific Reports
doi: 10.1038/s41598-019-50526-0
Figure Legend Snippet: An in vivo comparison of ECG (black), SPG (blue), and PPG (red) waveforms measured from a single subject. Because of the pulse transit time from the chest (ECG) to the finger (SPG/PPG), the ECG has its R peak before the SPG peak. SPG peaks before PPG.
Techniques Used: In Vivo, Comparison
Figure Legend Snippet: Corrected Artifacts (n = 17).
Techniques Used:
Figure Legend Snippet: A box plot comparison of the percentage of artifacts corrected for ECG (green), SPG (blue), and PPG (black) during the orthostatic challenge (n = 17). The circles represent outliers. Motion artifact and noise negatively impacted the peak detection algorithm accuracy, especially for PPG.
Techniques Used: Comparison
Figure Legend Snippet: A comparison of SPG, PPG, and ECG HRV time domain parameters (SDNN; ms and RMSSD; ms) for the 17 subjects during both sitting and standing conditions. SPG and PPG are compared to ECG on scatter plots with a line of best fit and the line of best fit equation, the Pearson’s correlation coefficient, and significance in the upper left corner of the plot. Each Bland-Altman plot corresponds to the scatter plot directly above it, with the mean difference (black line), the 95% upper and lower limits of agreement (blue dashed lines), and the acceptable upper and lower limits of agreement (red dashed lines) also plotted. It should be noted that the Bland-Altman plots for SPG and PPG have different y-axis scales.
Techniques Used: Comparison
Figure Legend Snippet: A comparison of SPG, PPG, and ECG HRV frequency domain parameters (LF; ms 2 and HF; ms 2 ) for the 17 subjects during both sitting and standing conditions. SPG and PPG are compared to ECG on scatter plots with a line of best fit and the line of best fit equation, the Pearson’s correlation coefficient, and significance in the upper left corner of the plot. Each Bland-Altman plot corresponds to the scatter plot directly above it, with the mean difference (black line), the 95% upper and lower limits of agreement (blue dashed lines), and the acceptable upper and lower limits of agreement (red dashed lines) also plotted. It should be noted that some of the Bland-Altman plots for SPG and PPG have different y-axis scales.
Techniques Used: Comparison
Figure Legend Snippet: A comparison of additional SPG, PPG, and ECG HRV frequency domain parameters (normalized HF; normalized units (n.u.) and LF/HF; ratio) for the 17 subjects during both sitting and standing conditions. SPG and PPG are compared to ECG on scatter plots with a line of best fit and the line of best fit equation, the Pearson’s correlation coefficient, and significance in the upper left corner of the plot. Each Bland-Altman plot corresponds to the scatter plot directly above it, with the mean difference (black line), the 95% upper and lower limits of agreement (blue dashed lines), and the acceptable upper and lower limits of agreement (red dashed lines) also plotted.
Techniques Used: Comparison
Figure Legend Snippet: Subjects remained seated for 5 minutes while a finger-clip device simultaneously collected SPG and PPG data and a wireless system collected ECG data. After a 30 second transition period for the subject to go from sitting to standing, 5 minutes of SPG, PPG, and ECG data were collected while the subject remained standing.
Techniques Used:
Related Articles
In Vivo:Article Title: Speckleplethysmographic (SPG) Estimation of Heart Rate Variability During an Orthostatic Challenge Article Snippet: For wireless ECG acquisition at 2000 Hz, we used a Nomadix Wireless Receiver with Comparison:Article Title: Speckleplethysmographic (SPG) Estimation of Heart Rate Variability During an Orthostatic Challenge Article Snippet: For wireless ECG acquisition at 2000 Hz, we used a Nomadix Wireless Receiver with |